Enviro Mini A Stove User Manual


 
Installation
DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE:
1. Check clearances to combustibles.
2. Do not obtain combustion air from an attic, garage or any unventilated space.
Combustion air may be obtained from a ventilated crawlspace.
3. Do not install the stove in a bedroom.
4. You can vent the stove through an exterior wall behind the unit or connect it to
an existing masonry or metal wood stove chimney (must be lined if the chimney
is over 6” (15 cm) diameter, or over 28 inches² (180 cm²) cross sectional area).
An interior vent can be used with approved pipe passing through the ceiling
and roof.
5. Locate the stove in a large and open room that is centrally located in the house.
This will optimize heat circulation.
6. The power cord is 8 feet (2.43 m) long and may require a grounded extension
cord to reach the nearest electrical outlet.
6
APPLIANCE DIMENSIONS AND SPECIFICATIONS:
Figure 1: Dimensions of Mini.
15
1
/4"
(386 mm)
19"
(483 mm)
17
1
/2"
(444 mm)
19
1
/2"
(496 mm)
17
7
/8"
(455 mm)
34
1
/8"
(868 mm)
19
3
/4"
(503 mm)
24
7
/8"
(632 mm)
ROOMAIR
FANON/OFF
ON/OFF
FEEDRATE
TRIM
COMBUSTION
BLOWERTRIM
HEATLEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
MODE
Weight (with full hopper): 238 lb (108 Kg)
Hopper Capacity: up to 48 lb (21.8 Kg)
Voltage: 110 - 120 V
Max Current: 4.1 Amps
Consumption on High: 3.1 lb/hr (1.4 Kg/hr)*
Consumption on Low: 1.3 lb/hr (0.6 Kg/hr)*
(Note: Consumption will vary with the type of
fuel used.)