Enviro EF3 Indoor Fireplace User Manual


 
Auger Trim
Auger Trim Auger Trim
2 Seconds
"ON"
3 Seconds
"ON"
Factory Setting
4 Seconds
"ON"
1 1 1
4
5
 

 

 
3. AUGER PULSE LIGHT: This light will flash in
conjunction with the auger.
4. MANUAL AUGER FEED: If the unit runs out
of fuel, this button can be used to “prime the
auger system”. This button will turn off after 60
seconds and then must be released and pressed
again.
5. SYSTEM LIGHT: Responsible for signaling
the state of the control board. When the light
is flashing during start-up, the stove is in an
automatic start mode. When the light is solid,
the Heat Level Setting can be altered.
6. ON/OFF BUTTON: Used to turn the unit ON
and OFF.
7. HEAT LEVEL INDICATOR: Shows the present
heat output setting.
8. HEAT LEVEL ADJUSTMENT: When pressed,
will change the heat setting of the unit from low
to high.
Operating Instructions
STOVE CONTROLS - CIRCUIT BOARD:
1. AUGER TRIM: The Auger Trim Button is used to increase or decrease the feed rate on LOW, ONLY.
Push the Auger Trim button until the number 1 and 5 lights appear on the Heat Level Indicator. This
will increase the feed rate to 4 seconds ON time Auger pulse. This is done only on LOW to allow the
burning of poor quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce
the Auger On time to 2 second. This setting is for high-grade fuel only. Push the button until just
the number 1 light is on, this is for a three (3) second on time (standard setting).
2. CONVECTION BLOWER CONTROL: Used to turn the convection blower ON/OFF. If the blower
is left off, and the sensor located on the air jacket reaches 160 °F (71 °C), the convection blower
will automatically come on HI speed to cool the unit. Leave the convection blower ON for peak
efficiency
Figure 2: Circuit board control panel.
Figure 3: Auger trim and heat level indicator.
7