Enviro 50-830 Stove User Manual


 
7
Operating Instructions
CONTROL BOARD FUNCTIONS:
1. AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim
button until the number 1 and 5 lights appear on the Heat Level Indicator. This will increase the feed
rate to four (4) seconds ON time Auger pulse. This is done only on LOW to allow the burning of poor
quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On
time to two (2) second. This setting is for high-grade fuel only. Push the button until just the number
1 light is on, this is for a three (3) second on time (standard setting).
 

 

 
1
3
4
5
6
2
8
7
2. CONVECTION BLOWER CONTROL: Used to turn the
convection blower ON/OFF. If the Blower is left off, and
the sensor located on the air jacket reaches 160 °F (71
°C), the Convection blower will automatically come on HI
speed to cool the unit. Leave the convection blower ON for
peak efficiency
3. AUGER PULSE LIGHT: This light will flash in conjunction
with the auger.
4. MANUAL AUGER FEED: If the unit runs out of fuel, this
button can be used to “prime the auger system”. This
button will turn off after 60 seconds and then must be
released and pressed again.
5. SYSTEM LIGHT: Responsible for signaling the state of
the control board. When the light is flashing during start-
up, the stove is in an automatic start mode. When the light
is solid, the Heat Level Setting can be altered.
6. ON/OFF BUTTON: Used to turn the unit ON and OFF.
7. HEAT OUTPUT INDICATOR: Shows the present heat
output setting.
8. HEAT LEVEL ADJUSTMENT: When pressed, will change
the heat setting of the unit from low to high.
Figure 3: Circuit Board Control Panel Decal.
Auger Trim
Auger Trim Auger Trim
2 Seconds
"ON"
3 Seconds
"ON"
Factory Setting
4 Seconds
"ON"
1 1 1
4
5
Figure 4: Auger trim and heat level indicator.