Enviro 2100 Stove User Manual


 
Installation
INSTALLATION:
A non-combustible oor protector is required under all freestanding units, refer to “Clearances To
Combustibles - Freestanding”. When venting into a masonry chimney the oor protector must be installed
directly below the chimney vent and 2” (50.8 mm) on either side of the chimney vent.
Vent the stove into a clean, lined, approved masonry chimney in good condition, conforming to local
building codes or a listed 6” (150 mm) factory built chimney suitable for use with solid fuels and conforming
to, ULC-S629 in CANADA or UL-103HT in the U.S.A.. Connect the stove to this chimney with a short and
straight 6” (150 mm), 25 gauge or heavier, single wall black or blued steel smoke pipe. Connection to all
masonry chimneys must be a metal or masonry thimble cemented in place. All smoke pipes must slope
upwards, all connections must be tight and secured with three sheet metal screws equally spaced. The
smoke pipe length should not exceed 40% of the chimney height above the stove.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.



 



 
  
 
 

     
     
    
 
    
  
 
NOTE: In installations where there is constant or frequent high winds, install a ue damper to reduce
the effect that high winds have on increasing the draft. A signicant increase in draft due to high winds
may cause your unit to overre, which could be hazardous and will void the warranty.
12