England's Stove Works 55-SHPEPI Stove User Manual


 
Page | 48
REPLACING COMPONENTS
Convection Blower
1. Before beginning any component
replacement, be certain the unit is
unplugged and thoroughly cooled
down.
2. Freestanding: Remove the right side
panel as previously detailed in this
manual on Page 41 in the “Exhaust
Blower Cleaning” section. Fireplace
Insert: The unit will need to be at
least partially removed from the
fireplace opening (or alternatively,
the surround kit and side panels can
be removed to access the blower).
3. Detach the convection blower from
the wiring harness before loosening
the four screws which secure it to the
convection shroud of the stove.
4. After loosening and removing the
four screws which hold the blower to
the stove, remove the blower from
the stove.
5. Installation of the new blower is
performed in reverse of removal;
remember to reconnect the new
blower to the wiring harness before
reinstalling the side panel.
Combustion Blower
1. Before beginning any component
replacement, be certain the unit is
unplugged and thoroughly cooled
down.
2. Freestanding: Remove the left side
panel as previously detailed on pg.
41. Fireplace Insert: Remove the
unit from the fireplace.
3. Disconnect the venting system from
the exhaust blower, and disconnect
the exhaust blower from the stove
wiring harness. Loosen and remove
the thermal sensor screw on the top
of the exhaust blower outlet using a
5/16” wrench.
4. Loosen and remove all five screws
which hold the exhaust blower to the
exhaust blower tube. Once the
screws have been removed, the
blower can be lifted up and out of the
stove.
5. Reinstallation is the exact opposite
of the steps above; however be
certain to check the condition of the
exhaust blower gasket and replace if
necessary.