England's Stove Works 55SHPAH Gas Heater User Manual


 
Page | 35
REPLACINGCOMPONENTS
Gaskets
1. Door
o Thisunitcomeswitha
5
/
8
ropegasketaroundthedoorthatshouldbereplaced
atleasteverytwoyears.Toreplacethedoorgasket(Part#ACDGKNC),theold
gasketmustfirstberemovedentirelypriortoaddingthenewadhesive,you
mayhavetoscrapetheoldcementfromthedoorchannel.Oncethecementand
gaskethavebeenadded,thedoorshouldbeclosedandlatchedfortwentyfour
hourstoallowthecementtoharden.
2. Window
o Ifyouarereplacingthewindowgasket(Part#ACGGK),thenewgasketwill
alreadyhaveadhesiveononeside.Removethepaperontheadhesivesideand
placethegasketaroundtheoutsideedgeoftheglass,centeredovertheedge.
Foldthegasketedgesoverontheglass,forminga“U”shape.
3. CombustionBlower
o TheCombustionBlowerGasket(Part#PUCBG)shouldbeinspectedwhenever
youremoveorcleantheCombustionBlowerandreplacedifnecessary.
4. CombustionBlowerMotor
o Thecombustionblowermotorgasket(Part#PUCMG)generallydoesnotneed
replacement,asitnotnormallyremovedfromtheunit.However,iftheexhaust
bloweriscleanedbyremovingthemotor,ratherthantheentireblower
assembly,thisgasketmustbeinspectedandreplacedasnecessary.
Finish
ThisnewunithasbeenpaintedwithHighTemperaturePaintthatshouldretainits
originallookforyears.Iftheunitshouldgetwetandrustspotsappear,thespotscanbesanded
withfinesteelwoolandrepainted.ItiscrucialthatonlyHighTemperatureSprayPaintisused
(Part#ACMBSP),asothersmaynotadheretothesurfaceorwithstandthehightemperatures.
Similarly,somebrandsofpaintwillnotadheretodifferentbrandsofpaint,sowehighly
recommendusingourproprietaryHighTemperatureSprayPaint.
IMPROPER GASKET MAINTENANCE, INCLUDING FAILURE TO REPLACE
GASKETS, CAN CAUSE AIR LEAKS RESULTING IN SMOKE-BACKS.