England's Stove Works 50SVL17 Stove User Manual


 
Page | 23
TROUBLESHOOTING
Issue Cause Solution(s)
Stovesmokesintoroom 1.WeakDraft 1.1Becertainchimneyissufficientlytallto
meetthe1032rule.
1.2Addadditionalheighttothechimney.
2.NegativePressurein
theHome
2.1Addanoutsidecombustionairhookupto
theunit.
Fireishardtostart 3.WeakDraft 3.1Becertainchimneyissufficientlytallto
meet1032rule.
3.2Addadditionalheighttothechimney
system.
4.ColdChimney 4.1Heatthefluefirstbyburningcrumbled
newspaperinthestove.
4.2Installaninsulatedchasearoundexternal
chimneys.
5.Downdraftin
Chimney
5.1Becertainchimneyissufficientlytallto
meet1032rule.
5.2Tryheatingthefluewithahairdryerto
correctthedraft.
Glassisdirty 6.WetorGreenWood 6.1Onlyburnwoodthatisseasonedforat
leastoneyearandthatisdryandfreeofice
andsnow.
7.OperatingStoveat
LowBurnRate
7.1Operatethestoveathigherburnratesto
allowtheairwashsystemtokeeptheglass
clean.
8.WoodLoadedToo
ClosetoGlass
8.1Neverloadwoodsothatitistouchingthe
ceramicglassviewingwindow.
Coalsbuildupinfirebox 9.OperatingStoveat
HighBurnRates
9.1Reducecombustionaircontrolandallow
coalstoburndownbeforereloading.
Fireburnsoutofcontrol 10.ExcessiveDraft 10.1Reducechimneyheight.
11.AirLeakage 11.1Inspectwindowanddoorgasketsand
replaceifnecessary.
12.BurningExcessively
DryWood
12.1Onlyburnseasonedcordwood.Donot
burnkilndriedwoodorpalletwood.
Excessivesmokefromstack 13.OperatingStoveat
LowBurnRate
13.1Operatethestoveatahigherburnrate
whichwillcreatesecondarycombustion.
14.WetorGreen
Wood
14.1Onlyburnwoodthatisseasonedforat
leastoneyearandthatisdryandfreeofice
andsnow.
15.NotCharringFresh
WoodLoad
15.1Charthefreshwoodloaduntilitis
completelyignitedandactivesecondary
combustionispresentinthefirebox.