England's Stove Works 49-SHC22 Stove User Manual


 
12.
Horizontal runs should not exceed four feet (4’) with a maximum vertical flue height of thirty
five feet (35’). At fifteen feet (15’), the pipe should be increased to four inch (4”) corn vent
pipe.
13. This unit should be turned off and allowed to cool prior to cleaning. Any ashes should be
kept in an airtight metal container and not disposed of until they are completely cooled.
14. Read the instructions thoroughly, including instructions concerning the digital control board,
and save them for future reference.
15. Do not allow paint, chemicals or construction dust on or near your unit. Do not allow liquid
or ANY foreign materials on or inside your unit. Shut your unit down and cover it when
painting, construction or similar activity is taking place. Wipe and clean your unit after any
construction is done in your home, or if any foreign material gets on or inside your unit.
You may also need to remove the rear and side cover plates to your unit (unplug unit first)
and vacuum and clean the motors and inside of your unit.
16. Improper gasket maintenance, including failure to replace gaskets, can cause air leaks
resulting in smoke-backs.
17. Remember that, as with any appliance, there is user responsibility involved, including
installation, operation and maintenance of this product. Be sure to check local codes, and
call Customer Service at (800) 245-6489 if you have any questions.
18. Be sure to follow the directions of all manufacturers of third party products that you
use, including exhaust pipe, etc. Never
apply firestarter products (including gel) to a
hot surface or hot coals.
19. Basement Installation: Basement installation should be performed only by a professional
installer. For basement installations, a 3” (three inch) pipe and coupler must be used for
Outside Combustion Air, and a minimum clearance of 3’ (three feet) must be maintained
from the ground to the corn vent exhaust pipe outside the dwelling. Keep in mind that each
elbow used reduces draft by up to 30%; it is good practice to add 3’ (three feet) of vertical
rise for each elbow used. Example: After the 2
nd
elbow used, add 6’ (six feet) of vertical
rise before terminating your vent pipe.
20. DANGER! Do not open the door on this unit if the stirrer is still moving! See instructions
on “Setting the Stirrer” later in this manual.
IMPORTANT NOTICE:
This unit must be properly installed to prevent the possibility of a house fire or “smoke-
back.” The instructions must be strictly adhered to.
Do not use makeshift methods or material which may compromise the installation.
Your unit requires periodic maintenance and cleaning (refer to manual). Failure to
maintain your unit may lead to a variety of problems, including but not limited to smoke
spillage into the home. England’s will not be liable for consequential or indirect damages
to
p
ro
p
ert
y
or
p
ersons resultin
g
from the use of this
p
roduct.
4