England's Stove Works 26-GULP Fan User Manual


 
GAS RATINGS
TYPE OF GAS NATURAL L.P./PROPANE
MAX. INPUT 34,500 BTU/HR 30,000 BTU/HR
MIN. INPUT 20,000 BTU/HR 20,000 BTU/HR
MANIFOLD PRESSURE 3.5” W.C. 10” W.C.
M/FOLD PRESSURE LOW 1.0/3.5” W.C. 4.5/10.0” W.C.
MIN. INLET PRESSURE 5.0” W.C. 11.0” W.C.
MIN. SUPPLY PRESSURE 5.5” W.C. 11” W.C.
MAX. SUPPLY PRESSURE 10.5” W.C. 14” W.C.
ORIFICE SIZE #34 #51
MINIMUM CLEARANCES TO COMBUSTIBLES
THIS APPLIANCE SHALL BE INSTALLED ON A METAL OR WOOD PANEL THAT
EXTENDS THE FULL WIDTH AND DEPTH OF THE APPLIANCE WHEN INSTALLED
ON A COMBUSTIBLE SURFACE OTHER THAN WOOD.
WARNING: WHEN USED WITHOUT FRESH AIR THIS HEATER MAY GIVE OFF
CARBON MONOXIDE, AN ODORLESS POISONOUS GAS.
OPEN A WINDOW AN INCH OR TWO FOR COMBUSTION AIR.
England’s Stove Works highly recommends the use of smoke detectors and
Carbon Monoxide detectors with any hearth product, including this unit. Follow all
manufacturer’s instructions when using smoke or Carbon Monoxide detectors.