Enerco HSIR30LPT Electric Heater User Manual


 
9
Installation Instructions and Owner’s Manual
Unvented Liquid Propane Fired Room Heater
Pressure Testing Heater Gas Connections:
1. Make sure that the heater supply piping sys-
tem is connected and has been leak tested as
described above.
2. Make sure control knob of heater is in OFF
position.
3. Open equipment shutoff valve (see gure 13).
4. Open propane/LP supply valve.
5. Check all joints from equipment shutoff valve
to control valve (see gure 14). Apply mixture
of liquid soap and water to gas joints. Bubbles
forming show a leak.
6. Correct all leaks at once.
7. Light heater (see Operating Your Heater, pages
11 and 12 for thermostat models or pages 9
and 10 for non-thermostat models). Check the
rest of the internal joints for leaks.
8. Turn off heater (see To Turn OFF Gas to Appli-
ance, page 12 for thermostat models and page
11 for non-thermostat models).
9. Replace lower front panel.
Figure 13
Figure 14
ELECTRICAL WIRING DIAGRAM:
Figure 15
If any original wiring as supplied with the heater must
be replaced, it must be replaced with type AWG 105
o
C
wire or its equivalent except as indicated.
WARNING: Electrical Grounding Instructions: This
heater is equipped with a three-prong (grounding)
plug for your protection against shock hazard and
should be plugged into a properly grounded three-
prong receptacle.
OPERATING YOUR HEATER
NON-THERMOSTAT MODELS
IR10LP / BF10LP
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a re or explosion may result causing prop-
erty damage, personal injury or loss of life.
A. This appliance has a pilot that must be lighted
by hand. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all around the appli-
ance area for gas. Be sure to smell next to the
oor because some gas is heavier than air and
will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call you gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
• If you can not reach your gas supplier, call the
re department.
Equipment
Shutoff Valve
Open
Closed
Gas Meter
Control Valve
Equipment
Shutoff Valve