Enerco HSIR30LPT Electric Heater User Manual


 
10
Installation Instructions and Owner’s Manual
Unvented Liquid Propane Fired Room Heater
C. Use only your hand to push in or turn the gas
control knob. Never use tools. It knob will not
push in or turn by hand, don’t try to repair it; call
a qualied service technician or gas supplier.
Force or attempted repair may result in a re or
explosion.
D. Do not use this appliance if any part has been
underwater. Immediately call a qualied service
technician to inspect the appliance and to re-
place any part of the control system which has
been underwater.
LIGHTING INSTRUCTIONS
1. STOP! Read the all safety information included
with and on the side of heater.
2. Check that gas supply to heater is on.
3. Push in gas control knob and slightly turn clock-
wise to the OFF position (see gure 16).
Note: Knob cannot be turned from PILOT to OFF
unless knob is pushed in slightly. Do not force.
4. Wait ve (5) minutes. Then smell for gas, in-
cluding near the oor. If you smell gas, STOP!
Follow “B” in the safety information above. If
you do not smell gas, go to the next step.
5. Push in gas control know slightly and turn
counterclockwise to PILOT/IGN and depress
for ve (5) seconds.
Note: The rst time that the heater is operated after
connecting the gas supply, the control knob should
be depressed for about 30 seconds. This will allow
air to bleed from the gas system.
6. Push in control knob and rotate control knob
back to OFF position then rotate counterclock-
wise to PILOT/IGN position. This will light pilot.
If needed gently keep rotating control knob
back and forth while depressed until pilot lights.
7. Keep control knob depressed in for ten (10)
seconds after lighting pilot. If pilot goes out,
repeat steps 4, 5, 6 and 7.
If pilot does not stay lit, refer to Troubleshoot-
ing, pages 14 & 15. Also, contact a qualied
service person or gas supplier for repairs.
• If control knob does not pop up when released,
contact a qualied service person or gas sup-
plier for repairs.
8. FOR IR10LP: When the pilot is lit, turn the con-
trol knob to “LO” position to light heater. Leave
on “LO” position until rst burner tile has turned
bright red (See gure18).
FOR BF6LP and BF10LP: When the pilot is lit,
turn the control knob to “HI” position to light.
9. FOR IR10LP: After rst burner tile has turned
bright red, adjust heat output by turning control
knob to desired position (“LO” or “HI”, gure
18). Do not operate heater between locked
positions.
FOR BF6LP and BF10LP: After ame is estab-
lished (see Burner Flame Pattern, Pages 12 and
13) on “HI”, adjust heat output by turning control
knob to desired position (“LO” or “HI”). Do not oper-
ate heater between locked positions.
Figure 16
CAUTION: Do not try to adjust heating level by using
equipment shutoff valve.
WARNING: When running heater, set control knob
at “LO” or “HI” locked positions. Poor combustion
and higher levels of carbon monoxide may result
if heater is operated with control knob positioned
between locked positions.
Figure 18.
IMPORTANT: Release downward pressure while turn-
ing control knob. Control knob must be locked at the
desired position.
LOW
HIGH
OFF
Control Knob
Figure 17
Note: Your heater may have either pilot assembly.
Burner tile pattern
for IR Heaters only.