Page 320101-0-0306
When used without adequate combustion and ventilation air,
heater may give off CARBON MONOXIDE, an odorless,
poisonous gas.
Do not install heater until all necessary provisions
are made for combustion and ventilation air. Consult
the written instructions provided with the heater for
information concerning combustion and ventilation
air. In the absence of instructions, refer to the National
Fuel Gas Code, ANSI Z223.1, Section 5.3 or applicable
local codes.
This heater is equipped with a PILOT LIGHT SAFETY
SYSTEM designed to turn off the heater if not enough fresh
air is available.
DO NOT TAMPER WITH PILOT LIGHT SAFETY
SYSTEM!
If heater shuts off, do not relight until you provide fresh air.
If heater keeps shutting off, have it serviced. Keep burner and
control compartment clean.
CARBON MONOXIDE POISONING MAY LEAD
TO DEATH.
Early signs of carbon monoxide poisoning resemble the flu,
with headache, dizziness and/or nausea. If you have these
signs, heater may not be working properly. Get fresh air at
once! Have heater serviced.
Some people — pregnant women, persons with heart or lung
disease, anemia, those under the influence of alcohol , those
at high altitudes — are more affected by carbon monoxide
than others.
The pilot light safety system senses the depletion of oxygen at
its location. If this heater is installed in a structure having a
high vertical dimension, the possibility exists that the oxygen
supply at the higher levels will be less than that at the heater. In
this type of application, a fan to circulate the structure air will
minimize this effect. The use of this fan will also improve the
comfort level in the structure. When a fan is used to circulate
air, it should be located so that the air flow is not directed at
the burner.
WARNING
An unvented room heater having an input rating of
more than 6,000 Btu per hour shall not be installed in a
bathroom
An unvented room heater having an input rating of more
than 10,000 Btu per hour shall not be installed in a bedroom
or bathroom.
Due to high temperatures, the appliance should be located
out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazard of high
surface temperature and should stay away to avoid burns
or clothing ignition.
Young children should be carefully supervised when they
are in the same room with the appliance.
Do not place clothing or other flammable material on or
near the appliance.
Installation and repair should be done by a QUALIFIED
SERVICE PERSON. This appliance should be inspected
before use and at least annually by a professional service
person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding materials, etc. It
is imperative that control compartments, burners and
circulating air passageways of the appliance be kept
clean.
DO NOT use this room heater if any part has been under
water. Immediately call a qualified service technician to
inspect the room heater and to replace any part of the
control system and any gas control which has been under
water.
You must operate heater with fireplace screen closed in
place. Do not close glass doors while operating heater.
Do not place trash, logs or other articles on the log set
during operation.
During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils,
films or bonding agents. These bonding agents are not
harmful but may produce annoying smoke and smells as
they are burned off during initial operation of the appliance.
This is a normal temporary occurrence. A window should
be opened during the initial bake out period.
Correct installation of the ceramic fiber logs, proper
location of the heater and annual cleaning are necessary
to avoid potential problems with sooting. Sooting, resulting
from improper installation or operation, can settle on
surfaces outside the fireplace. See instructions for proper
installation.
WARNING: Do not allow fans to blow directly into
the fireplace. Avoid any drafts that alter burner flame
patterns.
WARNING: Do not use a blower insert, heat exchanger
insert or other accessory not approved for use with this
heater.
WARNING! This fireplace needs fresh air for ventilation to
run properly. This fireplace has an ODS (oxygen depletion
sensor) which will shut down the heater if adequate fresh
air is not available. See troubleshooting section in the
instructions.
Keep appliance area clear and free from combustible
materials, gasoline and other flammable vapors and
liquids.
WARNING: Failure to keep the primary air opening(s)
of the burner(s) clean may result in sooting and property
damage.
IMPORTANT SAFETY INFORMATION