Empire Products SR-10T-3 Electric Heater User Manual


 
16009-1-0504 Page 9
SR-18T CLEARANCES
When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches (152mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the
appliance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.
Figure 5 (SR-18T)
SR-30T CLEARANCES
When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.
Left side 8 inches (203mm). Right side 8 inches (203mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the
appliance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.
Figure 6 (SR-30T)
36" (914mm) MIN
6" (152mm)
MIN
6" (152mm)
MIN
2" (51mm)
MIN
36" (914mm) MIN
8"
(203mm)
MIN
8"
(203mm)
MIN
2"
(51mm)
MIN