Emerson SST1400 Air Cleaner User Manual


 
9
REPLACING AN IONIZING WIREREPLACING AN IONIZING WIRE
REPLACING AN IONIZING WIREREPLACING AN IONIZING WIRE
REPLACING AN IONIZING WIRE
If an ionizing wire should break, it can be replaced as
follows:
1. Remove all pieces of broken wire. Make sure sup-
ports at each end are in good condition and not bent
out of shape.
2. Hook the new wire onto the support at one end.
3. Hold your finger against the support at the other end
(Figure 21) and hold the ionizing wire between thumb
and forefinger as shown or use needle nose pliers.
Press inward on spring support. Hook end of wire over
small tab at end of support and release. Make sure
wire is securely anchored at each end.
Support
Ionizing
Wire
Figure 21
Rated Capacity 600 - 1200 cfm 1000 - 1600 cfm 1000 - 2000 cfm 1600 - 2200 cfm
Max. Pressure Drop .08 in. W.G. .08 in. W.G. .12 in. W.G. .09 in. W.G.
Cell Weight (2) 7 lbs. each (2) 9 lbs. each (2) 9 lbs. each (2) 9 lbs. each
Power Pack Weight 9 lbs. 9 lbs. 10 lbs. 10 lbs.
Unit Weight 35 lbs. 42 lbs. 38 lbs. 45 lbs.
Power Consumption 40 Watts (Max) 40 Watts (Max) 40 Watts (Max) 40 Watts (Max)
Electrical Input 120 VAC 60 hz. 120 VAC 60 hz. 120 VAC 60 hz. 120 VAC 60 hz.
Electrical Output 1.0 Ma 1.2 Ma 1.5 Ma 1.7 Ma
@ 6450 VDC (nom)
Max. Ozone Output .05 ppm .05 ppm .05 ppm .05 ppm
Temperature Rating 40 F to 125 F 40 F to 125 F 40 F to 125 F 40 F to 125 F
SPECIFICATIONS SST1000 SST1400 SST1600 SST2000
SPECIFICASPECIFICA
SPECIFICASPECIFICA
SPECIFICA
TIONSTIONS
TIONSTIONS
TIONS