Emerson RP3228SL Home Safety Product User Manual


 
19
Replacing the Rechargable Ni-Cd battery pack
If after recharging, the battery power is still weak, replace the 4.8V 320mAH
rechargeable battery pack.
1.) Turn the unit on its side and use
a small screwdriver to remove
the screws securing the battery
compartment cover.
2.) Remove the compartment cover
by sliding it in the direction of
arrow”.
3.) Unplug the rechargeable battery
pack connector from the socket
and lift the pack out of the
compartment.
4.) Connect the new battery packs plug into the socket and place the battery
pack into the compartment.
Note:
The replacement Ni-Cd rechargeable battery packs are available from the Emerson
Customer Service Department. Please call 1-800-898-9020 and specify that you
need the replacement battery pack for model number RP3228 rechargeable
flashlight/radio. The part number is AAA320F4M57.
Caution: The supplied battery pack plug has the red wire toward the EARPHONE
jack when inserted correctly. To ensure proper polarity, only use the supplied or
recommended replacement battery pack.
5.) Replace the compartment cover and secured with the two screws.