Emerson CF905CK00 Fan User Manual


 
3
U.L. Model No.: CF905
EMERSON QUICK START GUIDE
The Quick Start Guide covers the installation
instructions common for ceiling fan operations. If
additional assistance with wiring, alternate hanging
systems, or lighting options, proceed to the complete
instructions of this Owner’s Manual.
The Quick Start Guide sections include page numbers
to correspond with the appropriate sections of the
Owner’s Manual for detailed instructions.
* See Unpacking Instructions for a complete list of
parts for installation.
1. Disconnect electrical power to the branch circuit at the circuit
breaker or fuse box before attempting to install the ceiling fan
hanger bracket on the outlet box.
2. Carefully pull the branch circuit wires though the center hole of
the mounting plate.
3. Attach ceiling mounting plate to outlet box using screws
supplied with box.
4. Hang the fan motor assembly onto the ceiling mounting plate
hook using the radial slot nearest the circular hole.
To reduce the risk of fire, electric shock, or
personal injury, mount fan to outlet box marked
“Acceptable for Fan Support of 15.9 kg (35 lbs) or
less", and use screws supplied with outlet box.
Most outlet boxes commonly used for support of
light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.
!
WARNING
OUTLET BOX
SCREWS (2)
CEILING
MOUNTING
PLATE HOO
K
CEILING
MOUNTING
PLATE
OUTLET
BOX
FAN MOTOR ASSEMBLY
CEILING
MOUNTING PLATE
HOOK
RADIAL SLOT
HOLE
How to Wire Your Ceiling Fan (page 8)
5. Connect the green grounding lead from the mounting plate and
the green grounding lead from the motor assembly to the
supply grounding conductor (this may be a bare wire or wire
with green colored insulation). Securely connect wires with
wire connectors supplied.
6. Securely connect the fan motor white wire to the supply white
(neutral) wire using wire connector supplied.
7. Securely connect the fan motor black wire to the supply black
(hot) wire using wire connector supplied.
8. Cap the blue fan wire with a wire connector if using the supplied
wall control.
9. After connections have been made, turn leads upward and
carefully push leads into the outlet box, with the white and
green leads on one side of the outlet box and the black and blue
leads on the other side of the outlet box.
FAN MOTOR ASSEMBLY
SUPPLY
BLACK WIRE
SUPPLY
WHITE WIRE
SUPPLY
GREEN WIRE
FAN MOTOR
BLUE WIRE
FAN MOTOR
BLACK WIRE
FAN MOTOR
WHITE WIRE
Turning off wall switch is not sufficient. To avoid possible electrical
shock, be sure electricity is turned off at the main fuse or circuit
breaker box before wiring. All wiring must be in accordance with
National and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical shock.
!
WARNING