1. Place the flange onto the blade. Secure the flange
to the blade using the four #10-32 x 8mm pan
head screws and four #10 flat washers (supplied).
Repeat for the four remaining blades. (Figure 1)
2. Place the upper glass shade into the styrofoam for
fan motor assembly.
3. Attach the fan motor assembly to the upper glass
shade using the four #10-32 x 10mm pan head
screws and lockwashers (supplied) (Figure 2).
4. Carefully turn the partially assembled fan motor
upside down and place into the styrofoam for
blade assembly installation.
5. Rotate the switch housing plate to align the holes
in the blade flange assembly with the holes in the
motor housing (Figure 3).
BLADE
#10-32 x 8mm
PAN HEAD SCREW
(4 Per Blade)
#10 FLAT LOCKWASHER
(4 Per Blade)
FLANGE
ASSEMBLY
#10-32 x 10mm
PAN HEAD SCREW (4)
LOCKWASHER (4)
UPPER GLASS
SHADE
FAN MOTOR
ASSEMBLY
STYROFOAM
Figure 2
BLADE FLANGE
ASSEMBLY
SWITCH
HOUSING PLATE
1/4-20 x 16mm OVAL
HEAD SCREW (2 per
flange assembly)
Figure 3
If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time
and remove the existing light fixture.
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with national and local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
WARNING
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support of 50 lbs. or Less”, and use screws
supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
WARNING
Electrical Requirements
Ceiling Fan Assembly
Procedures
To avoid possible fire or shock, follow all wiring
instructions carefully. Any electrical work not
described in these instructions should be done or
approved by a licensed electrician.
WARNING
4
IMPORTANT: Your ceiling fan is supplied with an
SW116 Fan/Light Wall Control (transmitter) and a
remote control SW105 Receiver which mounts
under the ceiling cover. This system allows you to
regulate your ceiling fan speed, airflow direction,
and light intensity. An optional Emerson Electric
SR110 Remote Control may also be used.
IMPORTANT: Your ceiling fan will not function
properly and may be damaged, if used with any
wall dimmer switch or control other than the
Emerson controls listed above.
Preliminary Procedures
IMPORTANT: Before assembling your ceiling fan,
refer to sections “Setting Operating Frequency of
Wall Control and Receiver” and “Installation of
Wall Control”, Page 11. These sections instruct
you how to:
a. Set the operating frequency of the fan/light wall
control and the remote control receiver.
b. Install the fan/light wall control in the wall box.
You will then be ready to proceed with the
assembly and installation of your ceiling fan.
U.L. Model No.: CF820
Figure 1