Emerson CF716ORB00 Fan User Manual


 
9. Turn the fan assembly upside down in preparation
for mounting the fan blade assemblies. Remove
and discard shipping retainers securing the motor
hub in the motor housing.
NOTE: Take care not to scratch fan housing when
installing blades.
10. Loosely attach one blade assembly to the motor
hub using two M6 x 14 captive screws with lock-
washers (Figure 6). Make sure the screws are
NOT tightened. Repeat this procedure for the
other four blade assemblies.
11. The blade flanges have an interlocking feature
that must be fully engaged before tightening the
screws. Make sure all the flanges are properly
engaged and then tighten the captive screws. If
one of the flanges does not seat properly on the
motor hub, loosen the adjacent captive screws,
re-engage and reseat the flanges, then tighten the
screws again.
12. Engage the connector of the switch housing
assembly with the motor connector (Figure 7).
The two connectors are keyed and color-coded
and must be mated correctly (color-to-color)
before they can be engaged. Make sure the
connector latch closes properly.
13. Remove the three mounting screws from the
switch housing plate (Figure 7). Position the
switch housing assembly on the switch housing
plate and secure using the three mounting screws
(Figure 8).
5
MOTOR HUB
FLANGE BLADE
M6 x 14 CAPTIVE SCREW
WITH LOCKWASHER
SWITCH HOUSING
PLATE
Figure 6
MOTOR
CONNECTOR
LATCH
SWITCH HOUSING
CONNECTOR
SWITCH HOUSING
ASSEMBLY
MOUNTING SCREW
Figure 7
Electrical Requirements
The outlet box must be securely anchored and capa-
ble of withstanding a load of at least 50 pounds.
If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support”, and use screws supplied with out-
let box. Most outlet boxes commonly used for
support of light fixtures are not acceptable for fan
support and may need to be replaced. Consult a
qualified electrician if in doubt.
WARNING
!
To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a
licensed electrician.
WARNING
!
U.L. Model No.: CF716
NOTE: Do not pinch wires between the switch
housing assembly and the switch housing plate.
14. You have now completed the assembly of your
new ceiling fan. You can now proceed with hang-
ing and wiring your fan.
FAN BLADE
BLADE FLANGE
M5 x 6 WASHER
HEAD SCREW (3)
Figure 5
To reduce the risk of personal injury, do not bend the
blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.
WARNING
!
MOUNTING SCREW
SWITCH HOUSING
ASSEMBLY
Figure 8