8. Turn the fan motor assembly upside down in
preparation for mounting the fan blade assemblies.
Remove and discard five shipping retainers
securing the motor in the motor housing.
NOTE: Take care not to scratch fan housing when
installing blades.
9. Loosely attach one blade assembly to the motor
using the two captive Phillips flange screws
(Figure 6). Make sure the screws are NOT tight-
ened. Repeat this procedure for the other four
blade assemblies.
10. The blade flanges have an interlocking feature that
must be fully engaged before tightening the
screws. Make sure all the flanges are properly
engaged and then tighten the flange screws. If one
of the flanges does not seat properly on the motor,
loosen the adjacent flange screws, re-engage and
reseat the flanges, then tighten the screws again.
11. Engage the connector of the switch housing
assembly with the motor connector (Figure 7).
The two connectors are keyed and color-coded
and must be mated correctly (color-to-color)
before they can be engaged. Make sure the
connectors close properly.
5
SWITCH
HOUSING PLATE
MOTOR CONNECTOR
SWITCH HOUSING CONNECTOR
SWITCH HOUSING ASSEMBLY
Figure 7
CAPTIVE PHILLIPS
FLANGE SCREW
M5 x 6mm SLOTTED
PHILLIPS WASHER HEAD
SCREWS (3)
RIB LINE
(THIS SIDE UP)
FAN BLADE
BLADE FLANGE
Figure 5
MOTOR
CAPTIVE PHILLIPS
FLANGE SCREW
BLADE FLANGE
Figure 6
SWITCH
HOUSING
ASSEMBLY
CAPTIVE
PHILLIPS HEAD
FLAT SCREW (3)
Figure 8
Electrical Requirements
The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.
If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
To reduce the risk of personal injury, do not bend the
blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.
WARNING
!
13. You have now completed the assembly of your
new ceiling fan. You can now proceed with
hanging and wiring your fan.
12. Position the switch housing assembly on the switch
housing plate and secure using three captive Phillips
flathead screws (Figure 8).
NOTE: Do not pinch wires between the switch
housing assembly and the switch housing plate.
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support of 50 lbs. or less”, and use screws
supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
WARNING
!