Emerson CF670BQ00 Fan User Manual


 
1. Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 1). Remove the pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in step 5.
2. Unscrew the two setscrews (Figure 2) until they
clear the inside of the motor coupling. Then
separate, untwist and unkink the three 80” motor
leads. Route the motor lead wires through the
downrod. Align the clevis pin holes in the downrod
with the holes in the motor coupling. Install the cle-
vis pin and secure with the hairpin clip (Figure 2).
The clevis pin must go through the holes in the
motor coupling and the holes in the downrod. Be
sure to push the straight leg of the hairpin clip
through the hole near the end of the clevis pin until
the curved portion of the hairpin clip snaps around
the clevis pin. The hairpin clip must be properly
installed to prevent the clevis pin from working
loose. Pull on the downrod to make sure the clevis
pin is properly installed.
3. Tighten the two setscrews (Figure 2) securely while
pulling up on the downrod.
NOTE: The setscrews must be properly installed
as described above, or fan wobble could result.
4. Make sure the grommet is properly installed in the
coupling cover, then slide the coupling cover on the
downrod until it rests on the motor housing. Place
the ceiling cover over the downrod. Be sure that
the ceiling cover and the coupling cover are both
oriented correctly (Figure 3).
5. Reinstall the hanger ball (Figure 4) on the downrod as
follows. Route the three 80” motor leads through the
hanger ball. Position the pin through the two holes in
the downrod and align the hanger ball so the pin is
captured in the groove in the top of the hanger ball.
Pull the hanger ball up tight against the pin and
securely tighten the setscrew in the hanger ball.
A loose setscrew could create fan wobble.
6. The fan comes with blue, black and white leads
that are 80-inches long. Before installing the fan,
measure up approximately 6 to 9-inches above top
of hanger ball/downrod assembly. Cut off excess
leads and strip back insulation 1/2-inch from end of
leads.
7. Mount blade flanges to fan blades using three
M5 x 6mm slotted Phillips washer head screws
(Figure 5).
IMPORTANT: THE SIDE OF THE FAN BLADE
HAVING THE RIB LINE MUST BE FACING
UPWARDS AS SHOWN IN FIGURE 5.
4
How to Put Your Ceiling Fan Together
PIN
HANGER
BALL
SETSCREW
DOWNROD
Figure 1
DOWNROD
COUPLING
COVER
CEILING
COVER
Figure 3
HAIRPIN
CLIP
DOWNROD
CLEVIS
PIN
MOTOR
COUPLING
SETSCREW (2)
Figure 2
PIN
HANGER
BALL
SETSCREW
DOWNROD
Figure 4
It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed (as shown in Figure 2) could
result in the fan falling.
WARNING
!
It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are proper-
ly installed could result in the fan falling.
WARNING
!