Emerson CF4600GLZ00 Fan User Manual


 
Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch circuit fuses
start. blown. or circuit breakers.
WARNING: Make sure main power
is turned off.
2. Loose power line 2. Check line power connections to fan.
connections to the fan, or
3. Fan/Light Wall Control is OFF. 3. Turn ON Fan/Light Wall Control.
4. Code switches in remote control 4. Check that both code switches
receiver and Fan/Light Wall Control are set in the same positions.
are not set in the same position
2. Fan sounds 1. Blades not attached to fan. 1. Attach blades to fan before
noisy. operating.
2. Screws securing fan blade 2. Check to make sure the
flanges to mounting hub are screws which attach the
loose. blade flanges to the mounting
hub are tight.
3. Wire connectors inside 3. Check to make sure wire
switch cup rattling. connectors in switch cup
are not rattling against each
other or against the interior
wall of the switch cup.
WARNING: Make sure main
power is turned off.
4. Screws holding blades to 4. Tighten screws securely.
flanges are loose.
5. Loose screws in motor 5. Check to make sure all
housing. screws in motor housing
are snug (not over-tight).
3. Fan wobbles 1. Setscrew in motor coupling 1. Raise upper housing/glass and
excessively. is not tightened securely. coupling cover, then
tighten setscrew securely.
2. Setscrew in the hanger ball/ 2. Tighten the setscrew in the
downrod assembly is loose. hanger ball/downrod
assembly.
3. Screws securing fan blade 3. Check to be sure screws
flanges to mounting hub which attach the fan blade
are loose. flanges to the mounting hub
are tight.
4. Fan blade flanges not 4. Check to be sure that the
seated properly. fan blade flanges seat firmly
and uniformly in the mounting
hub. If flanges are seated
incorrectly, loosen the flange
screws and retighten.
5. Hanger bracket and/or 5. Tighten the hanger bracket
ceiling outlet box is not screws to the outlet box,
securely fastened. and/or secure outlet box.
6. Fan blades out of balance. 6. Interchanging an adjacent
(side-by-side) blade pair can
redistribute the weight and
result in smoother operation.
Or use supplied balancing
kit to balance blades.
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX
OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.
!
!
!
Part No. F40BP73060001
Printed in China 06/06 Form No. BP7306-1
Air Comfort Products
DIVISION OF EMERSON ELECTRIC CO.
8100 W. Florissant ¥ St. Louis, MO 63136
BP7306 Nottingham 6/19/06 1:00 PM Page 20