Emerson CF3600AP Fan User Manual


 
FAN MOTOR
ASSEMBLY
DOWNROD
MOTOR
COVER
#8-32 x 1/4" PAN HEAD
SCREW (4)
Figure 6
MOTOR
COVER
COUPLING
COVER
DOWNROD
GROMMET
CEILING
COVER
Figure 7
14. Make sure the grommet is properly
installed in the coupling cover then
slide the coupling cover over the
downrod until it rests on the motor
housing cover. Place the ceiling cover
over the downrod. Be sure both the
ceiling cover and the coupler cover are
oriented correctly (Figure 7).
7
HAIRPIN
CLIP
CLEVIS PIN
MOTOR
COUPLING
5/16-18 x 1/4"
SETSCREW
Figure 5
the clevis pin. The hairpin clip must be
properly installed to prevent the clevis
pin from working loose. Pull on the
downrod to make sure the clevis pin is
properly installed.
11. Install the 5/16-18 x 1/4” setscrew into
the threaded hole on the motor
coupling.
12. While pulling up on the downrod,
securely tighten the 5/16-18 x 1/4”
setscrew (supplied) in the motor
coupling using the 3/16” hex wrench
(supplied) (Figure 5).
NOTE: The setscrew must be properly
installed as described above, or fan
wobble could result.
13. Carefully place the motor housing
cover over the downrod the guide it
over the motor housing assembly.
Align the three mounting holes with the
corresponding threaded holes on top
of the motor. Install three #8-32 x 1/4”
pan head screws into the holes to
secure the motor cover (Figure 6).
Model No.: CF3600
It is critical that the clevis pin in the motor
coupling is properly installed and the
setscrew securely tightened. Failure to
verify that the pin and setscrew are
properly installed (as shown in Figure 4)
could result in the fan falling.
!
WARNING
NOTE: Be careful not to scratch the
downrod with the ceiling cover during
installation.
BP7384 Camden, CF3600 2/18/09 2:57 PM Page 7