Emerson 36J Furnace User Manual


 
12 Gas Valve Cross Reference
36H Series
Universal Replacement Electronic Ignition Gas Valve. The
versatile 36H Series combination gas valves cover a wide range
of applications. Designed for use with common ignition systems
(HSI/DSI/Proven Pilot), it replaces hundreds of existing models in
the eld. The 36H Series is our highest capacity combination gas
valve.
Features
• HSI/DSI/Proven Pilot • Inlet/outlet screens
• Single Stage/Two-Stage • Electric on-off switch
• Fast/Slow Opening • Inlet/outlet pressure taps
• Convertible – natural or LP Gas • CSA approved
• Adjustable regulator(s)
Specications
Electrical Rating.....................................0.41 amps (Single Stage)
0.54 amps (Two-Stage)
Voltage...............................................................................24 VAC
Frequency........................................................................50/60 Hz
Operating Ambient Temperature .........-40° to 175°F (-40°to 79°C)
Pressure Rating (max.)...................................1/2 PSI (14.0" W.C.)
CENTERLINE OF
INLET & OUTLET
ALL DIMENSIONS
IN INCHES
INLET PRESSURE TAP
1/8" – 27 NPT
1.203
1.631
3.259
0.031
1.375
1.375
4.200 R
SWING RADIUS
3.984 INLET TO OUTLET
0.569
3.770
INLET 3/4" – 14 NPT
(PLASTIC DUST
PLUG INSTALLED)
1.125
PROVEN
PILOT PLUG
Model
Number
36H32-304
36H32-423
36H33-412
36H64-463
36H65-401
Voltage
24 VAC
24 VAC
24 VAC
24 VAC
24 VAC
Type of
Gas
Pipe
Size
1/2 x 3/4
3/4 x 3/4
3/4 x 3/4
3/4 x 3/4
3/4 x 3/4
Opening
Characteristics
Fast
Fast
Slow
Fast
Slow
Stages
1
1
1
2
2
HSI/DSI
Yes
Yes
Yes
Yes
Yes
Proven
Pilot
Yes
Yes
Yes
Yes
Yes
Standing
Pilot
No
No
No
No
No
Intermittent
Pilot
Yes
Yes
Yes
Yes
Yes
Convertible
Nat./LP
Kit Included
Yes
Yes
Yes
Yes
Yes
Reducer
Bushing
Kit
Yes
Yes
Yes
Yes
Yes
Inlet &
Outlet
Pressure Tap
Yes
Yes
Yes
Yes
Yes
Nat./LP
Nat./LP
Nat./LP
Nat./LP
Nat./LP
Pipe Size
(36 H)
3/4" x 3/4"
1/2" x 3/4"
1" PD Capacity
BTU/HR
Nat. Gas
2.5" to 5.0"
1.0" – 3.5" Low
2.5" – 5.0" High
LP Gas
5.0" to 12.0"
4.0" – 9.5" Low
8.0" – 12.0" High
Valve
Stages
Single
Stage
Two-
Stage
NAT GAS
0.64 Sp. Gr.
(1000 BTU/HR)
300,000
260,000
LP GAS
1.53 Sp. Gr.
(2500 BTU/HR)
486,000
421,000
Regulator
Adjustment
Range
Product Features and Specifications