10 Gas Valve Cross Reference
Cycle Pilot System
The thermostat calls for heat and simultaneously energizes pilot
solenoid and pilot relight control. Pilot valve opens and relight
begins sparking. Gas ow activates the pressure switch. Sparks
ignite pilot gas. Once the ame is detected, the sparks stop.
After sufcient heat is sensed by the Mercury Flame Sensor, the
main valve is energized and the system is in operating mode.
(Fig. 1)
The schematic for “ALL GASES,” Figure 2, includes a safety
timer which acts to close the main gas valve, turns off the pilot
redundant coil and locks out the system should a ame not be
detected within a xed period of time.