Elmo DSP 305 Home Security System User Manual


 
3.3 Configuration Services
Configuration services are available only in configuration mode. Some of the services
are only available to one LSS Slave device.
3.3.1 Configuration Node-ID
This service enables the LSS Master to configure the NMT-address of an LSS Slave.
Only one LSS Slave at a time can be configured with this service. A remote result
message confirms the success or failure of the service.
This service works in Configuration Mode. A change in the Node-ID causes a power-
on like reset to the device.
17 ## reserved for future use by CiA
012345678
COB-ID = 7E5h
CS NID
Figure 3-8 Switch the Node-ID of a Slave
NID (Node-ID):
If NID is set to FFh it becomes invalid when switching to operation mode. As a
result, the slave enters the ‘LSS Init State’ autonomously.
17 ## reserved for future use by CiA
012345678
COB-ID = 7E4h
CS
Error
Code
##
Specific
Error
Figure 3-9 Confirm the Node-ID of a Slave
Error Codes:
0: protocol successfully completed
1: Node-ID out of range
2 ... 254: reserved for further use by CiA
255: implementation specific error occured.
Specific Error Codes:
If error_code is 0 … 254, then a specific_error_code will be 0.
If error_code is 255, then a specific_error_code will be:
2: incorrect mode
no other options at this time
CANopen DSP 305 Implementation Guide
MAN-CAN305IG (Ver. 1.1)
3-4