12
Flash power J(Ws) 300 600 1200
Power supply 230V Version V all units 215-240
120V Version V all units 110-120
F-stop, 1m, 100 ISO, with reector 48° GN 64,1 90,1 128,1
Control range J(Ws) 9-300 18-600 36-1200
Recycling time 230V Version s 0,2-0,6 0,25-0,8 0,35-1,5
120V Version s 0,25-1 0,3-1,6 0,35-2,8
Flash duration (t 0,5) 1/1 s 1/2850 1/2050 1/1450
(t 0,5) 1/32 s 1/1350 1/850 1/480
Modelling lamp 230V Version W 250*/E27 250*/E27 300 GX 6,35
120V Version W 150/BA15D 150/BA15D 250/BA15D
120V «Canada Version» W 150/E27 150/E27 150/E27
Voltage across sync cable V 5 5 5
Connected load A/VA (W) 5/1150 6,3/1500 8/1840
Radio interference suppressiv CE-IEC 491 EN 60 555 - EN 61 000 - 4 - 2/3/4/5
Dimension length x diam. cm 21x14 21x14 30x14
Weight kg 2,15 2,45 3,45
Tolerances and specications conforming to IEC and CE standards.
Technical data subject to change without notice.
* Optional alternative 300W/GX6.35
Features
• Locking bayonet ring for accessory and reector tting
• Tilthead whit 5/8" - inch stand socket
• Thermal safety
• User replaceable ash tube UV coated (5650°K)
• Halogen modelling lamp 250W, with E27 tting, and
300W/GX6.35for Style 1200RX (230V Version)
• Silent fan cooling
• Controls for: modelling on/off, cell on/off, acoustic signal on/off.
• Flash and modelling power control.
• «X» synchro jack socket 3,5 mm.
• Socket for Plug-In remote control.
• Auto dumping function. Automatic discharge of ash power
• Central umbrella tube plus external tting
• Acoustic recharging signal
• Mains cable
• Synchro cord of 5m (jack 3.5mm plug)
• Protective cover
• Total compatibility with all Elinchrom accessories
• Very fast recycling time
• Very short ash duration
Technical data 300RX 600RX 1200RX