Elinca RX 300 Home Safety Product User Manual


 
6
10
Audible recharge signal
Select the function with the touch pad (8), the green indicator appears.
Once recycled an acoustic signal indicates that the compact unit is ready.
Open ash "test"
Having pressed the touch pad to release a ash, the green «READY» light will
appear again once the unit is recharged. If the green light does not appear the
charge system could be defective.
Please contact and send to an authorized Elinchrom service.
5
Test and Ready
Sychronisation socket
The standard socket 3.5 mm mini-jack (6).
N.B. Do not link ELINCHROM units by cable to other manufacturers sync outlets.
ELINCHROM uses the low voltage (5 V) for security reasons.
Sync
8
Beep
All RX units, Style RX, Digital RX, Ranger RX are equipped with the Remote Plug, to connect the
EL-Skyport Trigger and Remote System. With the EL- Skyport RX Trigger Set 19362,
the RX units can be triggered wireless, up to approximately 100 m distance. Apart from triggering,
the Transmitter offers modelling lamp on /off settings and ash power control in 1/10th steps.
By using the EL- Skyport Computer Remote / Trigger Set 19361, all RX functions can be
controlled and operated with a MAC° or Windows° computer.
For details of the most advanced wireless system please visit www.elinchrom.com > Products >
RX Multi Remote > EL-Skyport.
19361
19362
Wireless Remote Control and Flash Triggering
Troubleshooting
1. The mains switch (3) is ON ("I" position), but not light up:
• Switch OFF the unit and change the mains fuse (2)
• Use only time-lag fuse (16 AT), corresponding to the Style RX model
2. The switch (3) is lit, the open ash ready is lighting up but does not function.
• The ashtube in the ashhead may be faulty (see page 11)
• If replacing the ashtube does not solve the problem, the cause could be a
component failure => please return the unit to an authorised Elinchrom service.
3. The ON/OFF switch (3) is lit but the open ash signal (6) is not lit
• Temporary break for overheating, caused by fast ash sequences or ventilation
slots obturated
• Fan cooling defective => the unit turns off automatically and cannot be red any
more. After a break for cooling, the ash is ready again for operation.
• If after several minutes of break for cooling the ready signal (6) is not lit, the cause
could be a component failure. However, high voltage may remain on the capacitor
circuits. => DO NOT ATTEMPT TO REPAIR THE UNIT. In this case please send the unit
to an authorised Elincrom station.