Electrolux IH 18 Water Heater User Manual


 
3
When the appliance is operated with a
thermostatic mixer tap, the temperature
setting on the instantaneous water
heater must be around 8°C higher than
on the thermostatic mixer tap.
Recommendation for energy-saving operation:
40°C for washbasin, shower, and bath (knob tangibly engages).
55°C for kitchen sink. If this temperature
is no longer needed, the appliance
should be reset to the 40°C energy-
saving level.
Important instructions for the user
General
- Installation and startup should only ever be performed by an approved
installer or authorised installation firm.
- Before using the appliance, please read through these instructions
carefully. The manufacturer cannot accept any liability for damage
resulting from failure to follow these instructions.
- Fittings and connecting pipes may get hot. Therefore keep children well
away.
Operating the appliance
The ELECTROLUX IH electronic instantaneous water heater heats the water
as the latter continuously flows through it. When the hot water tap is opened,
the appliance switches on at a flowrate of around 3 l/min. When the hot water
valve is closed or if the flowrate is reduced below 2.5 l/min, the appliance
switches itself off again. The appliance is suitable for household use and should
only ever be used for heating of drinking water.
One or more tapping points can be supplied with hot water.
Temperature preselection
The electronic system allows continuous temperature selection in the range
from 30°C to 60°C.
Wash basin
Shower
Bath basin
Kitchen sink