3
G
2VJDL$POOFDU
Cord
Remote Controller Cord
Gas Supply Piping
Cold Water Supply
)PU8ater
Remote Controller
TFSNJOBM#MPDL
Cord
Connector
Cord
Connector
3.
Quick Connect Multi System Installation
r5IF2VJDL$POOFDU.VMUJ4ZTUFNBMMPXTUIFJOTUBMMBUJPOPGUXPVOJUTUPHFUIFSVUJMJ[JOHPOMZUIF2VJDL
Connect Cord.
Typical Plumbing
* When connecting two units, use only a
single remote controller.
Note: Connect the remote
controller to only one
of the units.
System Diagram
r*OTVMBUF UIFIPUXBUFS QJQJOH UPQSFWFOUIFBU MPTT *OTVMBUFBOEBQQMZ IFBUJOH NBUFSJBMT UP
the cold water supply piping to prevent heat loss and freezing of pipes when exposed to
excessively cold temperatures.
Union
Make this distance as short
as possible.
* The hot water temperature
will become unstable as the
pipe length increases.
Distance at center: 20.3 - 36.3 in. (515 - 922mm)
Quick Connect Cord
Union
Gas Valve
Union
Shutoff Valve
Shutoff Valve
Hot Water
Shutoff Valve
Cold Water
Distance on sides
2 - 18 in. (50 - 457mm)
Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.
Size the piping to allow for the
maximum ow rates of the units.
The backow preventer is
put up before it diverges.
5IF2VJDL$POOFDU$PSEJTGUNMPOH*OTUBMMUIFVOJUTNNBQBSUGSPNFBDI
other to ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).