8 9
33
34
36
37
38
35
* Certain models only.
Cleaning the motor lter and the dust con-
tainer lter
CycloneXL has a motor lter and a dust container lter
that should be cleaned now and then.
33 Open the front lid and lift out the dust container.
34 Dust container lter: Remove the lter holder
from the dust container and carefully pull the
dirty dust container lter out of the holder.
35 Motor lter: Pull the lter upwards until coming
away from the groove.
36 Rinse the lters in lukewarm water and let them
dry. Reattach the clean lters. Replace the dust
container and then close the lid.
Cleaning/replacing the exhaust lter*
There are three types of exhaust lter:
• Micro lter* (Ref. No. EF 17)
• Hepa H12* non washable (Ref. No. EF H12)
• Hepa H12* washable (can be bought as an option,
Ref. No. EF H12W)
The filters must always be replaced with new ones and
cannot be washed (except the Hepa H12* washable).
37 Open the back lid and lift out the filter.
38 Insert a new lter and close the lid.
42
39
40
41
43
44
* Certain models only.
Cleaning the hose and nozzle
The vacuum cleaner stops automatically if the nozzle,
tube, hose or lters become blocked and when the
dust container is full. In such cases, disconnect from
mains and allow to cool for 20-30 minutes. Clear
blockage and/or replace lters, empty the dust contai-
ner and restart.
Tubes and hoses
39 Use a cleaning strip or similar to clear the tubes
and hose.
40 Hose handle could be dismantled from hose if
cleaning is needed.
41 It may also be possible to remove the obstruction
in the hose by squeezing it. However, be careful
in case the obstruction is caused by glass or
needles caught inside the hose.
Note: The warranty does not cover any damage to the
hose caused by cleaning it.
Cleaning the oor nozzle
42 Be sure to frequently clean the combination oor
nozzle.
43* Press each wheel-hub and draw away the wheels.
Remove dust-balls, hair or other objects that may
be entangled.
44* Larger objects can be accessed by removing the
connection tube from the nozzle.
Cleaning the turbo nozzle*
45 Disconnect the nozzle from the vacuum cleaner
tube and remove entangled threads, etc. by
snipping them away with scissors. Use the hose
handle to clean the nozzle.
46a Disconnect the nozzle from the vacuum cleaner
tube and remove entangled threads, etc. by
snipping them away with scissors. Use the hose
handle to clean the nozzle.
46b In case the turbo nozzle stops working, open
the cleaning lid and remove any objects that
obstructs the turbine to rotate freely.
45