EdgeStar AP310SS Air Conditioner User Manual


 
probably rise by a few degrees (if you do not use the exhaust hose.)
The Dehumidifying mode will not work in temperatures below 64°F.
Cooling
1) Plug the power cord into a power outlet.
2) Turn on the unit.
3) Press the Mode button until the icon LED next to “Cool” lights up.
4) Select the fan speed by using the Fan button.
5) Set the thermostat using the Temperature / Time buttons. The thermostat is
adjustable between 64°F and 90°F in one degree increments.
Cooling mode cools and dehumidifies your air. If the ambient temperature drops below
the temperature you selected, the compressor turns off and the unit functions with the
fan only. When the temperature rises above the temperature you selected, the
compressor turns on again.
Note:
The exhaust hose must be used in Cooling mode in order to cool a room.
Fan-only
1) Plug the power cord into a power outlet.
2) Turn on the unit.
3) Press the Mode button until the LED next to “Fan” lights up.
4) Select the fan speed by using the Fan button.
Fan-only mode is used to circulate the air in your room. No temperature setting is
needed.
Note:
Fan-only mode does not require that the exhaust hose be attached.
4) Water Drainage
All air conditioners dehumidify the air as they cool. This portable air conditioner is
designed to evaporate and exhaust this condensed water (sometimes called condensate).
When using the Cooling or Dehumidifying modes under extremely humid conditions,
the internal water tray may fill completely. If this happens, the Water Level indicator
on the control panel will light and the compressor will shut off (so that no water is
spilled on the floor.) The unit will continue operating and exhausting water until the
water level lowers. Then the compressor will turn back on and the unit will begin
cooling as normal.
If you want to begin cooling or dehumidifying right away without waiting for the unit
to dispose of the excess condensate itself, you may manually drain the unit.
Manual Drainage
13
Turn the unit off. Unscrew the cap from the upper drain port. Connect a drain hose to
the upper drain port (one is included with this unit, or you may use a garden hose.) Put
the other end of the drain hose in a bucket. Turn the unit back on. The internal drain