EdgeStar AP14000HS Air Conditioner User Manual


 
Fig. 1
Installation
7
Duct Connector
Window Kit Connector
Exhaust Hose
2. Place one of the grated adapters(2) into one of the hole on flush side of the plastic window kit(1). Line
up the 4 holes in the grated adaptor(2) with the pilot holes in the plastic window kit and fasten them
together with a screw driver. Repeat for the other grated adaptor(2).
3. Install the plastic window kit(1) into your window. If necessary, use duct tape to better secure the window kit.
4. On the air conditioner, connect the duct connectors(4) (the connectors with the smaller slots) into the unit
by aligning the tabs inside the unit with the slots and snapping them together. (See Fig. 1).
Note: Once inserted, duct connectors cannot be removed.
5. Attach the window kit connectors(6) (the connectors with the larger slots) onto the exhaust hoses(5) by
stretching the hoses completely out and turning the window kit connectors(6) clockwise, screwing them
into the exhaust hoses(5).
6. Screw on the exhaust hoses(5) to the duct connectors(4) by turning them clockwise.
7. Move the air conditioner towards the window. Align the slots on the window kit connectors(6) to the tabs
on the grated adapters(2) and snap them together. (See Fig. 2)
8. To remove the window kit connectors(6) from the grated adaptors(2), push in the tabs on the grated
adaptors(2) and pull the window kit connectors(6) away from the grated adaptors(2)
9. To remove both the window kit connectors(6) and duct connectors from the exhaust hoses, twist the
connections counterclockwise. To remove the grated adaptors(2) unscrew the 8 screws(3).
10. The vent caps(7) may be installed on the grated adapters(2) (by aligning the slots with tabs and snapping
them together) when the air conditioner is not in use. (See Fig. 3)
1. Plastic window kit..............................2 pieces
2. Grated adapter..................................2 pieces
3. Screws..............................................8 pieces
4. Duct connector .................................2 pieces
5. Exhaust hose....................................2 pieces
6. Window kit connector........................2 pieces
7. Vent cap............................................2 pieces
Note: This unit can be used with one or two exhaust hoses. The exhaust hose(s) should alwaysbe used
in cooling mode. The air intake hose can be used to increase the cooling efficiency of the unit. If the air
intake hose is not used, simply cover one of the grated adapters on the plastic window kit with a vent cap.
4
1. Loosen the screws on the plastic window kit(1) and adjust the sliding kit to the width or height
of your window. Then tighten the screws to secure your adjustments to the window kit.
(See below images for setup examples)