EdgeStar ap12000s Air Conditioner User Manual


 
Modes
Cooling
Timer
High
Low
Medium
WATER
Fan Only
Dehumidify
Speed
Mode
Timer
POWER
Timer/Temp Set Buttons
After turning the air conditioner off, wait 3 minutes before turning it back on again.
During cooling mode, room air is cooled and hot
air is exhausted to the outside through the air
exhaust hose. Adjust the fan speed and
temperature to suit your desired comfort level.
Note: The air exhaust hose must be vented
through a window when using the cooling mode.
To set the temperature in cooling mode, use the up and down
buttons. The temperature setting range is from 61ºF - 89ºF.
Note: When in dehumidifying or fan modes, no
temperature setting is required or allowed.
This unit has 3 fan speeds: High, Medium and Low. Press the
speed button to toggle the speeds.
Temperature
• Used for adjusting the timer and thermostat.
The default display is room temperature.
• In cooling mode, you can set the temperature by
pressing the “▲” or “▼” button. The set temperature
will be displayed for 15 seconds, then revert back to
room temperature. The temperature is only adjustable
in cooling mode. The time is adjustable between 1-12
hours.
Note: By pressing both of the Timer/Temp button
the same time, the display will toggle between Celsius
and Fahrenheit.
Note: The displayed range of the ambient temperature
in both celsius and farenheit is from 0° to 99°. Any
temperature above 99° will be displayed as “HI” on
the indicator, and any temperature below 0° will be
displayed as “LO.”
Operation
W ater Light
Power Button
Mode Button
Fan Speed Button
The settings are toggled by the mode button.
Note: Your settings will be indicated on the
the control panel with an illuminated LED
This unit has 3 settings:
Cooling
This unit has 3 fan speeds: High, Medium and Low. Press
the speed button to toggle the speeds.
Note: The unit does not need to be vented in fan mode.
Cooling Mode
Fan Mode
Fan Speed
Dehumidifying
Fan
Display
Control Panel
Power
• The power button turns the unit on and off.
• When you first press the power button, the unit will
begin to operate in cooling mode. After you have
used the unit, and turned it off, it will default to the
last used mode/settings upon turning the unit on again.
If power to the unit is interrupted while the unit is running,
the air conditioner will restart itself in its last used
mode/settings once power is restored.
Note: This "auto restart" function will restart the
unit after power is restored. The compressor will
resume after 3 minutes, if it was on prior to the
interruption
Water Light
This portable air conditioner is designed to exhaust
most or all water condensed from the air (in cooling
mode). In high humidity situations, the internal water
reservoir may fill. The unit will automatically shut off
and the water light will turn on. Once the water is
manually drained, the unit will operate as normal.
Timer/Temp
Set Button
The dehumidifying mode removes water from the
air without cooling the room. If the room temperature
is below 77ºF, the fan speed will be locked on “low,”
above 77ºF, the fan speed is adjustable.
Note: The exhaust hose is not required in
dehumidifying mode.
Note: The internal water tray will fill with water in
this mode.
Dehumidifying Mode