Elitegroup TRW-1 Thermostat User Manual


 
REV.1/25/05 Page 5 of 9 Part #17810
To attach wall cover plate to receiver box:
1. Position the receiver as shown in diagram to the left with lower tab on
wall cover plate into groove of receiver (Make sure ADJ hole
and LEARN hole on cover plate properly aligns with remote receiver)
2. Pull receiver up and snap into top tab of cover plate.
3. Position the wall cover plate so the word ON is facing up.
4. Install the remote receiver into the plastic switch box using the two
long screws provided. Push the slide Button over the receiver slide
switch only after making sure the remote receiver has LEARNED the
transmitter’s security code (see MATCHING SECURITY CODES). NOTE: slide
button covers both ADJ and Learn holes when properly installed.
NOTE: The remote receiver will only respond to the transmitter when the 3-position
slide button on the remote receiver is in the REMOTE position. If the system does not
respond to the battery transmitter on initial use, see MATCHING SECURITY CODES,
and recheck battery positions in the remote receiver.
HEARTH MOUNT
The remote receiver can be placed on the fireplace hearth or under the fireplace, behind the control access panel. Position where the
ambient temperature inside the receiver case does not exceed 130
0
F.
NOTE: Black Slide Button is used for Hearth Mount applications.
WIRING INSTRUCTIONS
A qualified electrician or a gas technician who is familiar with the gas appliance and gas valves that will be operated by this remote
should install the remote control system. Incorrect wiring connections WILL cause damage to the gas valve or electronic module
operating the gas appliance and may also damage the remote receiver.
WIRING MILLIVOLT VALVES
The remote receiver is connected to the millivolt valve using the TH (thermostat) terminals on the terminal block on the millivolt gas
valve. Connect 18 gauge stranded or solid wires from the remote receiver to the gas valve.
Operation of the remote receiver is similar to that of a thermostat in that both turn the gas valve on
and off based on input signals. A thermostat’s input signals are different temperatures. The remote
receiver’s input signals come from the transmitter.
Connect each of the two wires leading from the TH and TH/TP terminals on the millivolt gas valve to
either of the two wire terminals on the remote receiver. Normally it does not matter which wires go to
which terminal.
Remote Receiver
MILLIVOLT
VALVE
REMOTE
OFF
LEARN
ADJ.
Frequency adjusting
access hole
ON
Learning
button
R
E
M
O
T
E
ON
OFF
LEARN
ADJ
.
REMOTE
ON
OFF
LEARN
ADJ.
WALL
Plastic Switch Box
Remote Receiver
Cover Plate
Receiver
Slide
Button
Remote Receiver
Cover Plate
(Rear View)