7.1.2. Opening
Warning: Do not open the handlamp within the Ex-hazardous area.
Before opening, switch to OFF.
The handlamp head is removed by turning anticlockwise from the
main casing – please note, that as the handlamp head is fitted with
a high integrity seal, this action can be difficult to start. To replace
the handlamp head, reverse the procedure – ensuring that the
handlamp head is screwed fully closed.
7.1.3. Bulb replacement
With the handlamp head removed the bulb is accessed by unscre-
wing - in an anticlockwise direction - the bulb retention socket.
Please ensure that only correctly specified bulbs are used.
7.1.4. Battery replacement
When the battery recharging capacity is becoming exhausted and
needs replacing only batteries as specified by ECOM can be used.
With the handlamp head removed the battery pack is removed by
sliding it out of the cavity of the main casing.
Replace in reverse procedure – ensuring that the contacts are
clean.
7.1.5. Battery charging
After engaging the handlamp into the charging station, LED’s indi-
cate the status and condition of operation. The handlamp can be
removed from the charging station at any time.
7.1.6. Emergency light mode
When the handlamp is switched on and then engaged in the char-
ging station, the emergency light mode function is automatically
activated. If the power supply to the charging station is then inter-
rupted, the handlamp switches on automatically - for a duration of
approximately 7 hours (when fully charged). Likewise, when then
removed from the charging station the handlamp switches on
automatically.