Draper 220V SLX Indoor Furnishings User Manual


 
www.draperinc.com
(765) 987-799
9
220V Scissor Lift by Draper page 6 of 6
Adjusting Show Position (Up to Standard Position)
Find the empty slot in the bottom of the top pan of lift (the only empty slot).
Use the open-end wrench (provided)
Find the threaded coupling (long nut) just inside the top pan (through the
slot).
Push wrench toward rear of unit to lower.
Pull wrench toward front of unit to raise.
Front of Unit
Decrease Show Position
(Stops Higher)
Increase Show Position
(Stops Lower)
Show Position
Adjustments
Front
Rear
Adjusting Scissor Lift “Show Position” Past Standard Position (46 cm)
If the desired show position is beyond the standard
position (46 cm) but not more than half the service
position, proceed to step #7.
If the desired show position is over half the
service position, proceed with the following steps.
Remove the top pan cover of the scissor lift.
Locate micro switches # 1 and #2 that are wired in series on the micro
switch assembly (see fi gure #1).
Disconnect the yellow wire from m/s #1 from the red wire from m/s #2.
Disconnect the black wire from m/s #1 from the green wire.
Connect the green wire to the red wire from m/s #2 (see fi gure #2).
At this point you can adjust the micro switch assembly, with
the supplied wrench, through the slot in the bottom of the top pan
(see above drawing).
After you have reached the desired show position, raise and
lower the unit several times in order to verify show position.
#2
Switch
Micro
COM
NC
Switch
COM
#1
NC
Micro
Figure A