B1600 - B2200
10
users ‘ instructions
GB
1 general informations
* according to EN 14511
1.6. Technical data
1.5.Description of the led state on the airdiffuser
LED
LED State Description
Off Airconditioner off
Orange
Airconditioner on StandBy (switch ON - aiconditioner is waiting for
a command)
Green Airconditioner is running
Red (fi xed)
Anomaly - 230V power supply missing (12V
is present)
Red (1 fl ick) Anomaly - Malfunctioning of the E1 temperature probe (internal)
Red (2 fl icks) Anomaly - Malfunctioning of the E2 temperature probe (external)
Description Unit
Model
B1600 B2200
Refrigerant gas (type/quantity) see data plate
Refrigerating yield Watt/h 1500* 2050*
Cooling consumption W 650 910
Heating capacity W 800 1200
Electrical rating V-Hz 230-50 230-50
Protection degree IP X4 X4
Conditioned air volume m
3
/h 310 380
Max internal volume of the vehicle (insulated walls) m
3
20 25
Weight Kg 30 34
235
650
310
min 30