Dometic 7020 Air Conditioner User Manual


 
5
English
L-2245
Wiring Diagram
(c.) DANGER - SHOCK HAZARD! Do not, under any
circumstances, cut or remove the grounding prong from the
end of your power cord. Your Carry-On must be used with a
three-prong grounding power cord and connected to a
properly grounded and polarized three prong receptacle. DO
NOT USE AN ADAPTOR PLUG, OR A TWO BLADE
ADAPTOR PLUG THAT BYPASSES THE GROUNDING IN
ANY WAY!!!
(d.) It is always desirable to have your on-board or shoreside
receptacle protected by a time delay fuse or circuit breaker.
7. If the Carry-On operation is interrupted (turned off, plug
pulled out, thunderstorm, etc., accidentally or otherwise)
after operation in the COOL mode, WAIT 3 MINUTES
BEFORE RESTARTING. This allows pressure inside the
compressor to equalize. Consequences of attempted restart
within the 3 minute period may be a tripped circuit breaker or
blown fuse. In this case, turn Carry-On to “OFF”, reset
breaker (or replace fuse), wait 3 minutes, then restart.
8. If the Carry-On has been stored in any position other than
upright within 10 degrees of level, then, after installing, wait
30 minutes to allow compressor oil to settle to the bottom of
the compressor. Otherwise permanent damage may occur,
voiding the warranty.