Dometic 39626.501 Air Conditioner User Manual


 
11
INSTALLATION INSTRUCTIONS
C
HERM
HERM
C
3108345.061
FIELD WIRINGFIELD
WIRING
FACTORY WIRINGFACTORY
WIRING
P4P3 P5
NC
P6
COM
K6
COM
NO
K1
F1
P1
P2
NO
T3
NC
T1
3 AMP FUSE3AMP FUSE
CIRCUITCIRCUIT
MOTOR
COND. BLOWERCOND.
BLOWER
EVAP. BLOWEREVAP. BLOWER
MOTOR
COMPRESSOR
R
C
S
OL
COMPRESSOR
S
C
OL
R
= WIRE NUT=WIRE NUT
ELEC.
BOX
BLKHD
SENSORSENSOR
AMB.
COMP
RED
WHT
START
CAP
STARTERSTARTER
STARTER
COMP
START
CAP
RUN
CAP
CAP
RUN
T2
DIP SWITCHESDIP SWITCHES
1
2
3
4
5
6
7
8
ON
BOARD
GRY
GRY
BRN
BLK
ORN
G-Y
GRY
ORN
YEL
YEL
BLU
BLU
BLK
ORN
WHT
G-Y
BLK
RED
BLK
BLK
BLK
WHT
WHT
RED
WHT
BLK
BLK
WHT
REDRED
WHT
GRY
WHT
BRN
ORN
BLK
CONTROL
FREEZE
EVAP. COILEVAP. COIL
WHT
FAN
BRN
CAP
MOTOR
BRN
BRN
BRN
BRN
WHT
BRN
RED
RED
WHT
WHT
ORN
RED
USE COPPER CONDUCTORSUSE COPPER CONDUCTORS
WHT
G-Y
BLK
ONLY
CIR.#2
115 VAC 60 Hz 1 PHASE115 VAC 60 Hz 1 PHASE
NATIONAL ELECTRIC CODENATIONAL ELECTRIC CODE
USE COPPER CONDUCTORSUSE
COPPER CONDUCTORS
ONLY
FIELD WIRING MUSTFIELD
WIRING MUST
COMPLY WITH THECOMPLY
WITH THE
CIR.#1
115 VAC 60 Hz 1 PHASE115 VAC 60 Hz 1 PHASE
BLK
G-Y
WHT
DIELECTRIC
PASSED
System Model 39626.501 & 39626.506*
Nominal BTU Capacity 26,000
Volts/Phase/Hertz (each circuit) 115 AC / 1 / 60
Run Amps Comp (Circuit 1 = 10.1) (Circuit 2 = 9.8)
LRA Compressor (Circuit 1 = 59.0) (Circuit 2 = 59.0)
Total Blwr/Fan Motor Run Amps 8.5 (Circuit 1)
Total Blwr/Fan Motor LRA Amps 18.0 (Circuit 1)
Duct Static - Min. ( In. Water Column) 0.40
Duct Static - Max. ( In. Water Column) 1.20
Generator Size Per/Unit - Min. *** 7.5K
Wire Size (Up to 24 ft.) ** (Circuit 1) No. 10 AWG Copper Conductors)
(Suggested) (Circuit 2) No. 12 AWG Copper Conductors)
Circuit Protection (Circuit 1) 25Amp
Time Delay Fuse or (Circuit 2) 15Amp
HACR Circuit Breaker
Control Voltage 12V DC
Refrigerant R-22
System Refrigerant Charge (Circuit 1 = 46.5) (Circuit 2 = 38.5)
Size (In Inches) Width Height Depth
46 18 22
Installed 205 Pounds
Weight
2.9 SPECIFICATIONS - AIR CONDITIONER
2. 8 WIRING DIAGRAM 39626.501 & 39626.506
**
Models ending with .506 suffix and manufactured with "SIDE AIR DISCHARGE".
For wire lengths over 24 ft. consult the National Electric Code for proper sizing.
The Manufacturer gives only general guidelines for generator requirements. These generator
requirements come from experiences consumers have with our equipment in field applications.
When sizing the generator, the total electrical power must be taken into consideration. Keep in
mind that generators lose power because of altitude increases above sea level , high outdoor
temperatures and lack of maintenance.
*
***