Dimplex VR20RP Electric Heater User Manual


 
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Models
Heating Elements Voltage Weight
VR15 1 x 1.5kW 230-240V 2.2kg
VR20RP 1 x 2.0kW 230-240V 2.2kg
Important Safety Advice
The installation of these appliances must always be
carried out by a competent electrician and be in
accordance with the current IEE wiring regulations and
relevant Building Regulations.
The radiated heat from the heater is considerable and
must be taken into account when siting the heater.
Ensure that the heater is not used in close proximity to
the skin or eyes.
Always isolate the heater from the supply before
undertaking any maintenance work of the appliance.
The Vector VR15 model is designed for internal use only,
whilst the VR20RP Patio Vector model can be internally
or externally installed. Both heaters are not rated as
flame-proof and must not be used when flammable dusts,
gases, or vapours, etc., are likely to be present in the
atmosphere. If in doubt, advice should be sought from
the Health and Safety Executive inspectors or local fire
officers.
Quartz lamps are extremely fragile and must be handled
with extreme care at all times. Avoid touching the surface
of the quartz sleeve with bare fingers. If the sleeve is
accidentally touched remove the finger print with a soft
cloth moistened with methylated spirits.
As with any fragile fitting mounted above head height,
care must be taken when siting the heater to avoid
locations where it may be subjected to knocks. In high
risk areas such as sports halls etc. extra guarding may
be required to protect the heater from flying objects. If in
doubt consult the heater manufacturer.
WARNING - THIS APPLIANCE MUST BE EARTHED.
HEATERS MUST BE MOUNTED OUT OF REACH FROM
OVERHEAD WALKWAYS AND OPENING WINDOWS. THE
HEATER MUST BE SECURELY FIXED AS IT WILL BE
DANGEROUS IN THE EVENT OF ANY INSECURITY IN ITS
FIXINGS.
General
The Dimplex Vector range is available in two models, 1.5kW
for internal use and a 2.0kW, which is suitable for both
internal and external installation. Both models are suitable
for permanent connection to a 230-240V 1PN supply.
Assembly
Vector VR15
Remove the front assembly (see Fig. 2) and disconnect
the lamp leads from the terminal block. Remove
knockout(s) as shown in Fig. 3. DO NOT attempt to
remove knockouts on assembled heater as this will
cause damage to the fragile lamps.
If a guard is to be fitted it is necessary to remove one
end cap from the heater front (see Fig. 4).
Vector VR20RP - Patio
Similar to Vector VR15 but rain cover must be removed
before front assembly can be removed (see Fig. 5).
Important
The supply cable MUST enter the back box from below on
this rain-proof model to prevent water entering the heater. If
the heater is to be wall mounted the two screws/nuts retaining
the cover support bracket will need to be removed.
Installation
The minimum mounting height from ground/floor is 1.8
metres for both models.
The heater should not be mounted in enclosed areas. The
minimum distance to an end wall is 1.0 metre. Large objects
should also be kept 1.0 metre away from the front of the
heater. Allow a minimum space of 150mm to any overhang
or ceiling - see Fig. 1.
Do not locate the heater above or below any socket outlet.
VR15
a. Wall mounting – screw back box to wall using 2 holes
(see Fig. 3).
b. Bracket mounting – fit bracket to wall and back box to
bracket (see Fig. 6).
c. Suspended mounting – remove 2 knockouts (see Fig.
3) and suspend back box using conduit or chain hooks.
VR20RP - Patio
a. Bracket mounting only – fit bracket to wall and back box
(cover support fitted) to wall bracket
(see Fig. 6).
IMPORTANT When deciding upon the best location,
consideration must be given to the following requirements.
a. Avoid structures liable to vibration, e.g. crane gantries,
which could otherwise adversely affect lamp life.
b. The lamps are designed to operate within 5° of the
horizontal plane. It is very important to ensure that the
heater is mounted horizontally, otherwise the operating
life of the lamp could be impaired.
c. Ensure appliance is mounted the correct way up so that
it can be tilted down but not up.
d. WARNING – THESE HEATERS ARE DESIGNED TO BE
WALL MOUNTED, BRACKET MOUNTED, OR
SUSPENDED MOUNTED – THEY MUST NOT BE
CEILING MOUNTED. THEY MUST NOT BE MOUNTED
IN A ROOM CONTAINING A BATH OR SHOWER. DO
NOT MOUNT HEATERS CLOSER THAN 3.5 METRES
FROM CURTAINS OR SIMILAR SOFT FURNISHINGS.
Electrical
Wiring to the heater must be installed in compliance with the
requirement of the IEE Regulations and any local or
insurance regulations.
All heaters are suitable for use on 230-240V single phase
supplies.
Wiring between the heater and the spur outlet or isolation
switch must be in a heat resisting cable with a temperature
rating of T150. Sufficient slack cable must be left to allow for
angular adjustment of the heater body.
An all-pole isolating switch with a minimum separation of
3mm in each pole must be fitted adjacent to the heater to
Dimplex VR15 & VR20RP Quartzray Vector Heaters