WARNING
Ensure method of installation does not obscure the
air intake slots on bottom of unit in any manner.
Keep minimum 4" clearance from bottom of unit to
any surface such as the top of a cabinet.
3. Wire a dedicated, properly fused circuit with
120V, 15amp rating. Allow up to 8 feet of service
cable for connecting power supply to junction
box on fireplace when installing after finishing
wall.
CAUTION
Use two conductor, non-metallic sheath cable with
ground wire (3 wires total) for the incoming power
supply on fireplace inserts. Use appropriate wire to
meet local and national electrical codes for rated
power consumption.
4. Remove the outer jacket and strip the individual
conductor from the end.
5. Loosen the screw securing the junction box
cover and remove the cover.
6. Take the cables out from the junction box,
loosen the two wire twist nuts and remove the
cord set. (FIGURE 6.)