Dimplex EWMC-CC-SS Indoor Fireplace User Manual


 
NOTE
A 15amp, 120 volt circuit is required. A dedicated circuit is preferred but not essential in all
cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or the
fuse blows on a regular basis when the heater is operating. Additional appliances on the same
circuit may exceed the current rating of the circuit breaker.
WARNING
Placing heavy objects on top of this fireplace may cause damage or injury.
Maximum suggested weight to be placed on top of unit is 25 lbs/11 kg.
Do not use fireplace as a seat or step.
WARNING
Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure
that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire,
electric shock or injury to persons.
Construction and electrical outlet wiring must comply with local building codes and other
applicable regulations to reduce the risk of fire, electric shock and injury to persons.
Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric
shock or injury to persons, always use a licensed electrician.
WARNING
The supplied mounting brackets are designed for use with Dimplex corner wall mounted
fireplaces only. Improper use, or use for purposes other than intended, may cause damage or
injury.
CORNER WALL MOUNTED ELECTRIC FIREPLACE INSTALLATION
WARNING
Failure to install the corner wall mounted electric fireplace as instructed below may result in
damage to the equipment and or may expose the user to the risk of fire, serious injury, illness
or death.
WARNING
The corner wall mounted electric fireplace requires each wall mounting bracket to be installed
into a minimum of one wall stud.
TOOLS
Drill, ½” drill bit, slotted screwdriver, angle divider, stud locator.
NOTE
For optimum installation the corner wall mounted
electric fireplace should be installed in a 90°
corner ± 3°. The use of washers (included) may
be required if the corner is not within the specified
tolerance.
1. Select the desired corner near an electrical
outlet. (power cord length is 5 feet)
2. Ensure the front of the unit when installed
is at least 3 feet (0.9m) from combustible
materials, such as furniture, pillows, bedding,
papers, clothes, and curtains.
3. Mount the unit in the corner with the bottom
trim being at a minimum of 15”
(mounting bracket 50”) above the floor.
(FIGURE 1 & 2)
NOTE
It is recommended that the bottom trim of the
unit not be mounted higher than 18” from the
ground (mounting bracket no higher than 53”).
(FIGURE 1 & 2)
FIGURE 2FIGURE 1
3