10
Remote Control
Initialization
Follow these steps for remote
control initialization and if
required, re-initialization:
1. Ensure that power is
supplied through the main
service panel.
2. Access the manual controls.
3. Locate manual controls.
4. Activate main power switch.
5. Press and hold the side of
the Manual Selection
Switch marked “ I ” for ve
(5) seconds (red indicator light will ash).
6. Press the ON button located on the remote control transmitter.
This will synchronize the remote control transmitter and receiver.
Battery Replacement
To replace the battery:
1. Slide battery cover open on the hand held transmitter (Figure 4).
2. Correctly install one (1) 12 Volt (A23) battery in the battery holder.
3. Close the battery cover.
Maintenance
WARNING: Disconnect power before attempting any maintenance
or cleaning to reduce the risk of re, electric shock or damage to
persons.
Light Bulb Replacement
WARNING: Allow at least ve (5) minutes for light bulbs to cool off
before touching bulbs to avoid accidental burning of skin.
Light bulbs need to be replaced when you notice a dark section of
the ame or when the clarity and detail of the log exterior disappears.
Figure 4
On
Button
Off
Button
Battery
Battery
Cover
Frequency Code