1. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases.
2.
Do not place propane/LP supply tank(s) in-
side any structure. Locate propane/LP supply
tank(s) outdoors (propane/LP units only).
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions
• if you cannot reach your gas supplier,
call the re department
4. This heater shall not be installed in a
bedroom or bathroom.
5. Before installing in a solid fuel burning re-
place, the chimney ue and rebox must
be cleaned of soot, creosote, ashes and
loose paint by a qualied chimney cleaner.
Creosote will ignite if highly heated. Inspect
chimney ue for damage. If damaged,
repair ue before operating heater.
6. Do not burn solid-fuel in a masonry or
UL127 factory-built replace in which a
vent-free room heater is installed.
7. If replace has glass doors, never operate
this heater with glass doors closed. If you
operate heater with doors closed, heat
buildup inside replace will cause glass to
burst. Make sure there are no obstructions
across openings of replace.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 20.
9. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
SAFETY
Continued
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
10. This heater needs fresh, outside air ven-
tilation to run properly. This heater has an
oxygen depletion sensing (ODS) pilot light
safety system. The ODS shuts down the
heater if not enough fresh air is available.
See Air for Combustion and Ventilation,
page 5. If heater keeps shutting off, see
Troubleshooting, page 21.
11. Do not run heater
• where ammable liquids or vapors are
used or stored
• under dusty conditions
12. Do not use this heater to cook food or burn
paper or other objects.
13. Do not use heater if any part has been ex-
posed to or under water. Immediately call
a qualied service technician to inspect
the room heater and to replace any part
of the control system and any gas control
which has been under water.
14. Do not operate heater if any log is broken.
Do not operate heater if a log is chipped
(dime-sized or larger).
15. Turn heater off and let cool before servicing
or repairing. Only a qualied service person
should install, service or repair heater.
16. This heater does not need to be con-
nected to any external electrical source.
17. To prevent performance problems, do not
use propane/LP fuel tank of less than 100
lb. capacity (propane/LP units only).
18. Operating heater above elevations of
4,500 feet could cause pilot outage.
19. Provide adequate clearances around air
openings.
UNPACKING
CAUTION: Do not remove the
-
1. Remove log set assembly from carton.
Note: Do not pick up assembly by logs.
This could damage heater. Always handle
assembly by grate.
2. Remove all protective packaging applied
to log set for shipment.
3. Check heater for any shipping damage. If
heater is damaged call FMI PRODUCTS,
LLC at 1-866-328-4537 for replacement
parts before returning to dealer.