MANTEL CLEARANCES
In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between replace openings and
mantel shelf on each side of the replace. If
you do not meet the clearances listed below,
you will need a hood.
If you meet minimum clearance between man-
tel shelf and top of replace opening, a hood
is not required (see Figure 6, page 10).
If minimum clearances in Figure 6, page 10
are not met, you must have a hood. When
using a hood there are still certain minimum
mantel clearances required. Follow minimum
clearances shown in Figure 7, page 10 when
using hood.
-
-
Follow all minimum clearances
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
-
FLOOR CLEARANCES
A. If installing appliance on the oor level,
you must maintain the minimum distance
of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14"
to the replace, you must install appliance
at least 5" above the combustible ooring
(see Figure 9).
INSTALLATION
Continued
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
14"
Min.
Combustible
Material
Noncombustible Material
Hearth
5"
Min.
Combustible
Material
CAUTION: Do not remove the
-
-
-
IMPORTANT: Make sure the heater burner is
level. If heater is not level, heater will not work
properly.
IMPORTANT: Remote receiver module is at-
tached to the valve by a velcro strap. This module
needs to remain where installed. If removed and
wires cross, this can cause the remote to fail.