Desa Wood Burning Fireplace Indoor Fireplace User Manual


 
www.desatech.com
106625-01D 3
Fireplace Screen: The fireplace screen
prevents sparks and embers from escaping
replace. Screen should always be closed
when a re is burning.
CAUTION: Screen handles
will become hot.
Fireplace Glass Doors (If Installed): Glass
doors must be fully opened or fully closed dur-
ing operation of your replace. Grate and/or
wood should not touch doors.
AIR CIRCULATION
During operation of replace, cool air enters
the rebox through lower grills. Heat rises and
is expelled into the room through top grill. This
is called convection heat.
UNDERSTANDING YOUR FIREPLACE
Continued
OPERATING YOUR FIREPLACE
1. Keep grate in brackets provided.
2. Open flue damper. During operation
damper must be in FULLY OPENED PO-
SITION. In cold weather, to assure proper
draw, preheat ue by burning a crumpled
newspaper in damper area after damper
has been fully opened.
3. Open combustion air damper (automatic
on some models).
4. Build a re using the following method:
• Use seasoned dry wood (should be
seasoned at least 1 year)
• Crisscross small pieces of wood and
place crumpled newspaper under it
• Place 3 logs on grate. DO NOT OVER-
LOAD FIREPLACE. Piling excessive
wood on the grate will not increase ef-
ciency and could cause smoke spillage.
• Light newspaper
5. Fireplace glass doors, if installed, must
be in fully opened or fully closed position
during operation of replace.
CAUTION: Close screen be-
fore closing glass doors.
WARNING: Fireplaces
equipped with glass doors
should be operated only with
doors fully opened or doors fully
closed. Doors, if left partly open,
may draw gas and ame out of
the replace opening creating
risks of both re and smoke.
Doors should warm gradually
to prevent breakage.
6. After re has burned out, do not close
damper until embers and ashes have had
a chance to completely cool and you are
certain there are no warm embers.
7. Dispose of ashes by using a metal con-
tainer with a tight lid. Do not remove ashes
until you are certain they are burned out
and have cooled completely.
This replace is not intended to
be used as a substitute for a fur-
nace to heat an entire home. Use
for supplementary heat only.
During periods of extremely cold weather,
when replace is not being used, the exact
opposite may happen. Warm room air will
enter upper grill due to extreme cold air near
outside of metal rebox. Air cools, drops and
re-enters room through lower grill.
This may be an indication the cold climate
installation procedure was not used.
WARNING: Never block a
vent or grill of the replace. This
is important to the cooling of the
replace and assures a safe and
proper operation as designed.