Desa VYS18PB Electric Heater User Manual


 
www.desatech.com
113093-01H 23
OPERATION Continued
REMOTE READY MODELS

1. Press the POWER and LOCK buttons
together to turn on the hand-held remote
control.
2. Press AUTO button to select this mode.
3. Set the desired room temperature by
pressing the TEMP + or - buttons.
4. Press the POWER and LOCK buttons
together to turn off the replace
Note: Do not leave the hand-held remote in
the AUTO mode close to the replace. The
radiant heat from the replace will turn off the
replace. Ideally, place the hand-held remote
in the center of the room facing towards the
replace.
Note: Do not hold the hand-held remote for
a long time. Body temperature will affect its
operation in the AUTO mode.
Safety Features
When away from home for an extended period
of time or as a child safety feature to prevent
accidental ignition of the replace, the receiver
ON/OFF/REMOTE switch should be in the
OFF position.
Auto Shutoff Feature
1. If the average room temperature reach-
es a range of 82° F (28° C) to 92° F (33°
C), the hand-held remote control will
perform a safety override and shut the
replace off. This feature is not available
in the MANU mode.
2. The receiver continuously receives sig-
nals from the hand-held remote to control
Figure 30 - Thermostat Hand-Held
Remote Control Unit (HRC200)
LOCK
MANU AUTO
ºC/ºF
TEMP
POWER
ROOM
TEMP
SET
TEMP
AUTO
Turns
Hand-Held
Remote On
or Off and
Allows You
to Choose
the Manual
Setting
Selects
AUTO
Mode
°C/°F Mode
Button
Locks
System to
Prevent
Accidental
Ignition
Turns
Burners
On or
Off
Increases or
Decreases Room
Temperature in
AUTO Mode
Digital Display Shows
Temperature and Settings
the room temperature. If the hand-held
remote is misplaced, obstructed or
for any reason cannot transmit to the
receiver, the receiver will shut off the
replace. This will occur in 8 or more min-
utes depending upon location of remote
transmitter and strength of batteries.

This feature allows the user to lock/unlock the
keypad on the hand-held remote in the MANU
or AUTO mode to prevent inadvertent op-
eration (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK
buttons together to turn the unit on or off.
INSPECTING BURNERS
Check pilot ame pattern and burner ame
patterns often.

Figure 31 shows a correct pilot ame pattern.
Figure 32 shows an incorrect pilot ame pat-
tern. The incorrect pilot ame is not touching
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools,
the heater will shut down.
If pilot ame pattern is incorrect, as shown
in Figure 32
turn heater off (see To Turn Off Gas to Appli-
ance, page 19 [Manually-Controlled Models]
or page 21 [Remote-Ready Models])
see Troubleshooting, page 26
Note: The pilot ame on natural gas units will
have a slight curve, but ame should be blue
and have no yellow or orange color.
Figure 31 - Correct Pilot Flame Pattern
(Your pilot may vary from pilot shown)
Pilot Burner
Thermocouple
Pilot Burner
Thermocouple
Figure 32 - Incorrect Pilot Flame Pattern
(Your pilot may vary from pilots shown)