Desa VyS18NC Electric Heater User Manual


 
www.desatech.com
124452-01A 15
INSTALLATION
Continued
Equipment Shutoff Valve
Propane/LP
Supply Tank
Control Valve
Location
Figure 16 - Checking Gas Joints
(Natural Gas Only)
Gas
Meter
Equipment Shutoff Valve
Control Valve Location
Figure 15 - Checking Gas Joints
(Propane/LP Gas Only)
3. Check all joints from gas meter (natural
gas) or propane/LP supply to equipment
shutoff valve (see Figure 15 or 16). Apply
a commercial leak detection solution to all
joints. Bubbles forming show a leak.
4. Correct all leaks at once.
INSTALLING LOGS


  



CAUTION: After installa-

   





-

It is very important to install these logs exactly
as instructed. Do not modify logs. Only use
logs supplied with heater.
1. Place grate into square holes on heater
base as shown in Figure 17.
2. Place front log on burner so that it sits
between grate ngers and burner (see
Figure 17).
Figure 17 - Installing Grate and Logs

CONNECTIONS
1. Open equipment shutoff valve (see Figure
14, page 14).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from gas meter (natural
gas) or propane/LP supply to equipment
shutoff valve (see Figure 15 or 16). Apply
a commercial leak detection solution to all
joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operation page 16).
Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to
Appliance, page 17).
Grate
Heater Base
Front Log
The Front Log Should Be
Centered Left To Right.