INSTALLATION
Continued

   
    
   

-

  

CAUTION: Never connect
  

-
 


WARNING: Never connect

   
    

Figure 13 - Attaching Base to Fireplace
Floor (Variable Manually-Controlled
Models Only)
Masonry
Screw
Bracket
with Screw
Holes
Installation Items Needed
Before installing heater, make sure you have
the items listed below.
external regulator (supplied by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
test gauge connection *
sediment trap
tee joint
pipe wrench
* A CSA design-certied equipment shutoff
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase
the optional CSA design-certied equipment
shutoff valve from your dealer.
For propane/LP units, the installer must
supply an external regulator. The external
regulator will reduce incoming gas pressure.
You must reduce incoming gas pressure to
between 11" and 14" of water. If you do not re-
duce incoming gas pressure, heater regulator
damage could occur. Install external regulator
with the vent pointing down as shown in Figure
14. Pointing the vent down protects it from
freezing rain or sleet.
CAUTION: Use only new,
     -


     




Propane/LP
Supply Tank
External
Regulator
Figure 14 - External Regulator With Vent
Pointing Down
Vent
Pointing
Down