Desa (V)V36P Indoor Fireplace User Manual


 
108861-01D
For more information, visit www.desatech.com
For more information, visit www.desatech.com
15
15
VENTING INSTALLATION
INSTRUCTIONS
Continued
Vertical Venting
V = 40' max.
Figure 24 - Vertical Venting Configuration With No Horizontal
Run (Vertical Round High Wind Termination Shown)
Note:
Install restrictor
into inner collar of
fireplace as shown.
45° Elbow
HIGH ALTITUDE INSTALLATION
Your DESA International direct-vent fireplace has been CSA tested
and approved for elevations from 0-2000 feet (USA) and elevations
from 0-4500 feet (Canada) .
When installing this fireplace at an elevation above 2000 feet (in the
USA), you may need to decrease the input rating by changing the
existing burner orifice to a smaller size. Reduce input 4% for each
1000 feet above sea level. Check with your local gas company for
proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in
Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice
for your location.
For assistance with any high altitude installation contact DESA
International’s Customer Service Department at 1-866-672-6040.
VENTING INSTALLATION INSTRUCTIONS
Installation for Vertical Termination (Cont.)
High Altitude Installation
Parts Lists for Venting Kits and Components for V36 and V42 Model Series
PARTS LISTS FOR VENTING KITS AND
COMPONENTS FOR V36 AND V42 MODEL
SERIES
DESA International (5/8") Pipe & Vent Kits
Number Description
01492 Horizontal Square Termination Kit
Includes: 45° Elbow (Through 5" Wall), Wall Firestop,
Horizontal Square Termination
01493 Basic Vertical Termination Kit
Includes: Vertical Termination, Adjustable Flashing,
Storm Collar
01491 Horizontal Round Termination Kit
Includes: Round Termination, Wall Firestop, and
45° Elbow (Through 5" Wall)
01497 12" Section Coaxial Pipe - Galvanized (4)
01498 18" Section Coaxial Pipe - Galvanized (4)
01499 24" Section Coaxial Pipe - Galvanized (4)
01500 36" Section Coaxial Pipe - Galvanized (4)
01501 48" Section Coaxial Pipe - Galvanized (4)
01513 6" Section Coaxial Pipe - Galvanized (4)
01606 Adjustable 17"-24" Section Coaxial Pipe -
Galvanized (4)
F8030 Adjustable 7"-12" Section Coaxial Pipe - Galvanized (6)
D1032 Adjustable 7"-12" Section Coaxial Pipe - Galvanized (1)
DESA International Elbows
Number Description
01502 45° Elbow - Galvanized (4)
01503 90° Elbow - Galvanized (4)